{"id":5507,"date":"2024-10-18T17:32:27","date_gmt":"2024-10-18T15:32:27","guid":{"rendered":"https:\/\/cofinair.com\/case-studies\/anti-corrosion-coating\/"},"modified":"2026-10-07T14:05:06","modified_gmt":"2026-10-07T12:05:06","slug":"anti-corrosion-coating","status":"publish","type":"project","link":"https:\/\/cofinair.com\/it\/case-studies\/anti-corrosion-coating\/","title":{"rendered":"Corrosion in cooling towers: the Cofinair coating"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Corrosion on cooling towers? The solution is our special coating.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>When ordinary maintenance proves providential. Following ordinary maintenance activities on some non-Decsa-manufactured cooling towers for a Client based in the province of Alessandria, Italy, and specialised in the production of special polymers, our technicians found a corrosion problem on the cooling towers, which was later solved with our special DecsaProt coating.<\/em><\/p>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2560\" height=\"1280\" src=\"https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-scaled.webp\" alt=\"Case study of anti-corrosion coating\" class=\"wp-image-1610\" srcset=\"https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-scaled.webp 2560w, https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-300x150.webp 300w, https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-1024x512.webp 1024w, https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-768x384.webp 768w, https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-1536x768.webp 1536w, https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/DecsaProt-anti-corrosion-coating-2048x1024.webp 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">The Customer Problem<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">It is spring 2024 when Cofinair by Decsa&#8217;s\u00a0Service\u00a0team travels to the Customer, a major chemical company based in the province of Alexandria, Italy, to carry out the usual planned ordinary <a href=\"https:\/\/cofinair.com\/it\/services\/manutenzione\/\" data-type=\"service\" data-id=\"639\"><strong>maintenance<\/strong><\/a> on four cooling towers not manufactured by Decsa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During the intervention, Cofinair by Decsa technicians found a significant corrosion problem inside the water basin of the units installed at the plant. After a careful analysis of the problem, the bid definition and formalisation of the order (September 2024) followed.<\/p>\n<\/div>\n\n<div class=\"wp-block-group alignwide blue_gradient_background is-layout-grid wp-container-core-group-is-layout-8c0afae9 wp-block-group-is-layout-grid\">\n<div class=\"wp-block-group has-custom-css is-layout-constrained wp-block-group-is-layout-constrained wp-custom-css-c684f6ed\">\n<h2 class=\"wp-block-heading\">The solution: anti-corrosion painting in cooling towers<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The intervention, carried out promptly as early as October 2024, first consisted of the removal of corrosion formed inside the water collection basin of two of the NON-Cofinair manufactured cooling towers installed at the site. Subsequently, Decsa&#8217;s Service technicians proceeded with the related application of DecsaProt painting (note that due to plant requirements, the Client requested painting for only two units, postponing the intervention for the other two until next year).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>DecsaProt treatment<\/strong>, in fact, is indicated for the recovery of damaged components and consists of a cleaning operation from present corrosion and subsequent repainting of galvanised steel components with a special paint called &#8220;DecsaProt.&#8221;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Applicable even on non-Decsa manufactured cooling towers, this coating can\u00a0<strong>extend the life of<\/strong>\u00a0the unit, limiting rust reforming and achieving an attractive safeguard of the main investment*.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once again, we see the importance of carrying out the usual ordinary maintenance activities to preserve the performance of the cooling tower and prevent downtime of the equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With our scheduled maintenance service, it is possible to schedule periodic interventions by Decsa Service (with annual or multi-year contracts) to ensure ordinary maintenance of cooling tower components and control of perishable parts. Moreover, entering into a maintenance contract allows the Customer to have priority in the management of interventions, ordinary and extraordinary, as well as an ad-hoc price list.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><sub>*<\/sub><\/strong><sub>It should be specified that although painting is an important protection against corrosion, it is essential to check the proper treatment of water in cooling towers; another activity that, if requested, is\u00a0<\/sub><strong><sub>offered free of charge<\/sub><\/strong><sub>\u00a0by Cofinair using professionals in the field.<\/sub><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-custom-css is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-e310e333 wp-block-group-is-layout-flex wp-custom-css-b8584fa4\"><div class=\"related-element-wrapper post-service\">\n    <a href=\"https:\/\/cofinair.com\/services\/cooling-tower-retrofit\/\" class=\"related-element-image-link\">\n        <img decoding=\"async\"\n            src=\"https:\/\/cofinair.com\/wp-content\/uploads\/2026\/02\/services_improvement-300x225.webp\"\n            alt=\"Retrofit &amp; upgrades\"\n            class=\"related-element-image\" \/>\n    <\/a>\n    <div class=\"related-element-content\">\n        <h2 class=\"related-element-title\">\n            <a href=\"https:\/\/cofinair.com\/services\/cooling-tower-retrofit\/\">\n                Retrofit &amp; upgrades            <\/a>\n        <\/h2>\n        <div class=\"related-element-excerpt\">\n                            <p class=\"p1\">We support the modernisation of your existing installations through cooling tower retrofit and upgrade solutions. By enhancing performance, reliability, and energy efficiency, we extend the lifespan of your equipment while adapting it to evolving operational and environmental requirements.<\/p>\n                    <\/div>\n        <a href=\"https:\/\/cofinair.com\/services\/cooling-tower-retrofit\/\" class=\"related-element-link\">\n            Read more        <\/a>\n    <\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Company<\/th><th class=\"has-text-align-left\" data-align=\"left\">Manufacturer of special polymers<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Place of Installation<\/td><td class=\"has-text-align-left\" data-align=\"left\">Spinetta Marengo (AL), Italy<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Type of interlocutor<\/td><td class=\"has-text-align-left\" data-align=\"left\">End Client<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Application<\/td><td class=\"has-text-align-left\" data-align=\"left\">Process cooling<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">equipment<\/td><td class=\"has-text-align-left\" data-align=\"left\">cooling tower crossflow NOT owned by Decsa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Services Provided<\/td><td class=\"has-text-align-left\" data-align=\"left\">Anti-corrosion painting intervention (DecsaProt)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n","protected":false},"featured_media":5508,"template":"","meta":{"_acf_changed":false},"class_list":["post-5507","project","type-project","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/cofinair.com\/it\/wp-json\/wp\/v2\/project\/5507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cofinair.com\/it\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/cofinair.com\/it\/wp-json\/wp\/v2\/types\/project"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cofinair.com\/it\/wp-json\/wp\/v2\/media\/5508"}],"wp:attachment":[{"href":"https:\/\/cofinair.com\/it\/wp-json\/wp\/v2\/media?parent=5507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}